- Welcome to Accuthermo Technology Corp.
- A Total Thermal Solution Provider
Transmitters | Sensors & Transmitters
Category Name: Sensors Transmitters
-
- ISC 2-Channel Isolated Universal Signal Converter/Conditioner/Isolator
- •The unique Math function.
PV1,PV2 is the measuring value of Channel 1 and Channel 2 separately. A,B,C is a constant set by user.
•The unique High/Low comparison output.
The output 1 can scale to PV1 or PV2 whichever is higher/lower than the other.
•Programmable for various input signals and measuring range.
•Configurable without Power Connected.
•Full 3-way isolation for 1500 Vrms.
•DIN rail mount.
•Dual channel Input.
Resistance thermometer (Pt100)
Thermocouple (J,K,T,E,B,R,S,N,C)
Voltage/Current transmitter (mV/V/mA)
•Dual 0/4 to 20 mA or 0~10V analogue output (ISC-D).
•RS485 communication interface with Modbus RTU protocol (ISC-C).
•Fault signal on sensor break presettable.
-
- ISD 2 Independent Channels Isolated Universal Signal Converter/Conditioner/Isolator
- •Two independent input channels for various input signals and measuring range
•Configurable without Power Connected.
•Full 3-way isolation for 1500 Vrms.
•DIN rail mount.
•Dual channel Input:
Resistance thermometer (Pt100)
Thermocouple (J,K,T,E,B,R,S,N,C)
Voltage/Current transmitter (mV/V/mA)
•Dual 0/4 to 20 mA or 0~10V analogue output (ISD-D).
•RS485 communication interface with Modbus RTU protocol (ISD-C).
•Fault signal on sensor break presettable.
-
- IST-D Microprocessor Based Programmable lsolated Signal Transmitter
- DIN rail mount
Programmable for various input signals and measuring range
Configurable without Power Connected
3750 Vrms isolation between input and output
Input:
Resistance thermometer (PT100)
Thermocouple (J,K,T,E,B,R,S,N,C)
Voltage/Current transmitter (mV/V/mA)
Output :
2-wire loop-power technology, 4 to 20 mA analog output.
Fault signal on sensor break presettable.
-
- IST-P Isolated 3 wire potentiometer transmitter
- Up to 15 User defined linearization points available.
The user linearization feature allows the volume of a tank’s contents to be calculated from the height of the material in that container. Up to 15 linearization points can be defined by user in the measurement range.
Configurable without Power Connected.
3750 Vrms isolation between input and output.
2-wire loop-power technology, 4 to 20 mA analogue output.
Fault signal on sensor break presettable.
Accept 200 ~ 60K ohms 3 wire Potentiometer input.
Head mount.
-
- IST-H Microprocessor Based Programmable lsolated Signal Transmitter
- Head mount
Programmable for various input signals and measuring range
Configurable without Power Connected
3750 Vrms isolation between input and output
Input:
Resistance thermometer (PT100)
Thermocouple (J,K,T,E,B,R,S,N,C)
Voltage/Current transmitter (mV/V/mA)
Output :
2-wire loop-power technology, 4 to 20 mA analog output.
Fault signal on sensor break presettable.