Part Number
The unit will come standard with PT100, -200~600°C, you can change the input Type/Rang using the free software " ![](/upload/images/products/Sensors%20%26%20Transmitters/iSignalwin-logo-02.jpg) " with the configuration cable URC-1020, or you can contact us for non-standard Input/Rang setting.
Model No. |
Mount type |
IST-H |
Head mount |
The ![](/upload/images/products/Sensors%20%26%20Transmitters/iSignalTrans-logo-02.jpg) IST-H is user configurable using our ![](/upload/images/products/Sensors%20%26%20Transmitters/iSignalwin-logo-02.jpg) software on your PC/notebook or our dedicated handheld programmer. The easy to use ![](/upload/images/products/Sensors%20%26%20Transmitters/iSignalwin-logo-02.jpg) software is available free from your supplier or can be downloaded from our web site and should be used in conjunction with the URC-1020 USB cable which incorporates an interface converter necessary for communications.The IST-H transmitter can be configured without any loop or power connected making it easy to configure in the workshop before installation.
The unit will come standard with PT100, -200~600°C, you can change the input Type/Rang using the free software "" with the configuration cable URC-1020, or you can contact us for non-standard Input/Rang setting.
Specification
Input |
Thermocouple (T/C) : industry standard thermocouple types J, K, T, E, B, R, S, N, C (ITS-90). |
Pt100: Excitation 180uA. 2 or 3 wire connection (ITS-90 α =0.00385). |
Voltage: -60mVdc to 60mVdc or –10Vdc to 10Vdc. |
Current : 0-24mAdc |
Accuracy |
Refer to Table 1 Input Signal |
A/D Resolution
|
16 bits |
Input Sampling Rate
|
<200ms |
Power supply |
DC 10 to 36V |
Max. Load |
(V-10)/0.02 ( Ω ) |
Output Resolution
|
0.6 μ A(15 bits) |
Output Response time
|
<200ms |
Common Mode Rejection Ratio(CMRR) |
>80dB |
Electromagnetic compatibility |
En 50081-2, En 50082-2 |
Galvanic isolation |
3.75 KV. between input and output |
Operating Temperature |
-40 to 85 ° C |
Humidity |
0 to 90% RH |
Table 1 Input Signal
Input signal |
Maximum Range |
Accuracy |
Thermocouple J |
-50 to 1000 ° C (-58 to 1832 ° F ) |
± 1 ° C |
Thermocouple K |
-50 to 1370 ° C (-58 to 2498 ° F ) |
± 1 ° C |
Thermocouple T |
-270 to 400 ° C (-454 to 752 ° F ) |
± 1 ° C |
Thermocouple E |
-50 to 700°C (-58 to 1292°F) |
± 1 ° C |
Thermocouple B |
0 to 1750 ° C (32 to 3182 ° F ) |
± 2 ° C (Note1) |
Thermocouple R |
-50 to 1750 ° C (-58 to 3182 ° F ) |
± 2 ° C |
Thermocouple S |
-50 to 1750 ° C (-58 to 3182 ° F ) |
± 2 ° C |
Thermocouple N |
-50 to 1300 ° C (-58 to 2372 ° F ) |
± 2 ° C |
Thermocouple C |
-50 to 1800 ° C (-58 to 3272 ° F ) |
± 2 ° C |
Pt100 |
-200 to 600 ° C (-328 to 1112 ° F ) |
± 0.2 ° C |
mV |
-60mVto 60mV |
± 0.01m V |
Voltage (Note2) |
-10 to 10Vdc |
± 1m V |
Current (Note2) |
0 to 24mAdc |
± 10μA |
Note 1 : Accuracy is not guaranteed between 0 and 400°C (0 and 752°F) for type B
Note 2 : If you require either mV V or mA please specify with order.
Dimension
Wiring Diagram
Block Diagram
Download
![](/upload/images/products/Fl200911041031291175.jpg) |
![](/upload/images/products/Fl200911041032022246.jpg) |
![](/upload/images/products/Fl200911041031291175.jpg) |
Manual |
ISWinC100625 |
Data sheet |
Accessories
![](/upload/images/products/Sensors%20%26%20Transmitters/Fl201001190139522328.jpg) |
![](/upload/images/products/Sensors%20%26%20Transmitters/Fl201001190140097829.jpg) |
EzPro Handheld Programmer |
URC-1020 Interface Cable |
|